作者单位:1. 中山医科大学,分子医学研究中心,广东,广州,510089
2. 中山医科大学,附属第一医院检验部,广东,广州,510089
摘    要:用色谱-质谱法测定血浆中洛伐他汀,采用辛伐他汀作内标,以乙酸乙酯为萃取液,经真空抽干,定容进样。洛伐他汀质量浓度在0.36~48mg/L之间线性关系较好。该法灵敏度高,前处理简单快速,检出限达0.1mg/L,相对标准偏差小于8.9%,回收率大于92%。

关 键 词:洛伐他汀  色谱-质谱法  血浆  降血脂药  测定
文章编号:

Determination of Lovastatin in Human Plasma by GC-MS
ZHENG Wen-hui,CAI Kui-hua,WU Yao-liang.Determination of Lovastatin in Human Plasma by GC-MS[J].Journal of Instrumental Analysis,2000,19(4):69-70.
Authors:ZHENG Wen-hui  CAI Kui-hua  WU Yao-liang
Abstract:A method for the determination of lovastatin in human plasma was established by GC-MS with ion monitoring mode. Simvastatin was used as an internal standard. Sample was extracted by ethyl ace_tate, and then the extractive was used to detect after vacuum drying and fixed volume. The standard curve is linear in the range from 0.36 to 48 mg/L for lovastatin with correlation coefficient of 0.995. The method is sensitive with detection limit of 0.1 mg/L. The relative standard deviation(RSD) for intra _ day detection was found to be less than 5.0%, while RSD for inter _ day detection to be less than 8.9%. The recoveries are more than 92%.