Determination of lead concentration and lead isotope ratios in calcium supplements by inductively coupled plasma mass spectrometry after high pressure, high temperature digestion
Authors:Dula Amarasiriwardena  Kamal Sharma  R M Barnes
Institution:School of Natural Science, Hampshire College, Amherst, MA 01002, USA, US
Department of Chemistry, Lederle Graduate Research Center Tower, University of Massachusetts, Box 34510, Amherst, MA 01003-4510, USA, US
Abstract:The presence of lead as a contaminant in calcium supplements has aroused considerable public health interest in recent years. In this investigation lead and lead isotope ratios were determined by ICP-MS in ten brands of calcium supplements after high pressure/temperature digestion. Calcium supplements (200 to 250 mg) were digested in 2 mL of nitric acid at 230?°C and at a pressure of 1770 psi (1.2 × 104 kPa). Lead concentrations were determined by matrix-matched lead standards prepared in a high-purity calcium carbonate matrix. Good recoveries of lead and calcium were obtained for certified animal bone reference material. High levels of Pb (8 to 28 μg Pb per g of calcium) were found in calcium supplements that contain dolomite or bone meal. Chelated and refined calcium supplements had lower Pb levels (0.8 to 0.9 μg Pb/g Ca). Application of lead isotope ratios to distinguish the origin of calcium sources was also explored.