摘    要:本文研究分析扭摆法测量转动惯量实验的系统误差来源,在此基础上对实验方法、装置提出改进,改进后实验结果与理论值的百分差可降低一至二个数量级.

关 键 词:扭摆  转动惯量  系统误差  实验改进

THE SYSTEMATIC ERROR IN MEASUREMENT OF ROTATIONAL INERTIA BY METHOD OF TORSION PENDULUM AND THE IMPROVEMENTS ON THE EXPERIMENT
Tang Zhao Zhang Yihu. THE SYSTEMATIC ERROR IN MEASUREMENT OF ROTATIONAL INERTIA BY METHOD OF TORSION PENDULUM AND THE IMPROVEMENTS ON THE EXPERIMENT[J]. Physics and Engineering, 2000, 0(1)
Authors:Tang Zhao Zhang Yihu
Affiliation:Zhanjiang Oceanology University Zhanjiang 524088 China Geological University Wuhan 430074
Abstract:The origin of systematic error in measurement of rotational inertia by method of torsion pendulum is investigated. On the basis of the investigation,some improvements are made respectively on the experiment method and the experiment device,which could reduce the percent error between experimental result and theoretic value from 10 to 100 times.
Keywords:torsion pendulum  rotational inertia  systematic error  improvement on the experiment  