首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Ion chromatographic determination of bromate in drinking water by post-column reaction with fuchsin.
Authors:M Achilli  L Romele
Institution:ENEL SRI, Polo Ambiente, Segrate, MI, Italy.
Abstract:Bromate deriving from ozonation treatment of bromide containing waters are analyzed by ion-exchange chromatography with spectrophotometric detection after post-column reaction with fuchsin in low pH medium. An anion-exchange column was used with 2.7 mM carbonate-0.3 mM hydrogencarbonate eluent. The eluent from the column was then allowed to react with a SO2-reduced fuchsin solution and then with a diluted HCl solution at 65 degrees C. The developed colour of the final product was measured spectrophotometrically at 530 nm. Linearity was checked up to 50 micrograms/l with a 200-microliter injection loop (r2 = 0.9997) and up to 100 micrograms/l of bromate with 100 microliters loop (r2 = 0.9939). Nitrate, sulfate, bromide, phosphate, fluoride did not interfere at 100 mg/l concentration level; only nitrite at concentration levels greater than 3 mg/l caused partial overlapping with bromate peak, but this value is not likely to occur in common drinking water. The detection limit (3 sigma) is 0.1 microgram/l (1 microgram/l propagation error approach).
Keywords:
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号