首页 | 本学科首页   官方微博 | 高级检索  
     


LOW POWER MEASUREMENTS ON THE NEW RF OUTPUT SYSTEM OF A 170 GHZ, 2 MW COAXIAL CAVITY GYROTRON
Authors:T. Rzesnicki   J. Jin   B. Piosczyk   M. Thumm   G. Michel  D. Wagner
Affiliation:(1) Forschungszentrum Karlsruhe GmbH, Institut für Hochleistungsimpulsund Mikrowellentechnik, P.O. Box 3640, D-76021 Karlsruhe, Germany;(2) Universit?t Karlsruhe, Institut für H?chstfrequenz und Elektronik, 76128 Karlsruhe, Germany;(3) Max-Planck-Institut für Plasmaphysik, 17491 Greifswald, Germany;(4) Max-Planck-Institut für Plasmaphysik, 85740 Garching, Germany
Abstract:The design of the quasi optical (q. o.) RF output system for the first industrial prototype of the European 170 GHz, 2 MW, CW coaxial cavity gyrotron for electron cyclotron heating and current drive in ITER has been verified at a low power level. Results of measurements with a high quality TE34,19-mode generator are in good agreement with the design calculations. This strengthens the confidence both to the employed design codes and to the manufacturing quality of the launcher and mirrors.
Keywords:Coaxial Cavity Gyrotron  RF Output System  Quasi Optical Converter  Low Power Measurements  Electron Cyclotron Heating