Calibration and Limits of Camera‐Based Fluorescence Correlation Spectroscopy: A Supported Lipid Bilayer Study
Authors:Nirmalya Bag  Jagadish Sankaran  Alexandra Paul  Prof Dr Rachel S Kraut  Prof Dr Thorsten Wohland
Institution:1. Departments of Biological Sciences and Chemistry and NUS Centre for Bio‐Imaging Sciences, National University of Singapore, 14 Science Drive 4, Singapore 117546 (Singapore);2. Singapore‐MIT Alliance, E4‐04‐10, National University of Singapore, 4 Engineering Drive 3, Singapore 117576 (Singapore);3. School of Biological Sciences, Nanyang Technological Institute, 60 Nanyang Drive, Singapore 637551 (Singapore);4. Department of Biophysical Chemistry, Saarland University, Saarbrücken 66123 (Germany)
Abstract:Camera‐based fluorescence correlation spectroscopy (FCS) approaches allow the measurement of thousands of contiguous points yielding excellent statistics and details of sample structure. Imaging total internal reflection FCS (ITIR‐FCS) provides these measurements on lipid membranes. Herein, we determine the influence of the point spread function (PSF) of the optical system, the laser power used, and the time resolution of the camera on the accuracy of diffusion coefficient and concentration measurements. We demonstrate that the PSF can be accurately determined by ITIR‐FCS and that the laser power and time resolution can be varied over a wide range with limited influence on the measurement of the diffusion coefficient whereas the concentration measurements are sensitive to changes in the measurement parameters. One advantage of ITIR‐FCS is that the measurement of the PSF has to be performed only once for a given optical setup, in contrast to confocal FCS in which calibrations have to be performed at least once per measurement day. Using optimized experimental conditions we provide diffusion coefficients for over ten different lipid membranes consisting of one, two and three constituents, measured in over 200000 individual correlation functions. Using software binning and thus the inherent advantage of ITIR‐FCS of providing multiple observation areas in a single measurement we test the FCS diffusion law and show how they can be complemented by the local information provided by the difference in cross‐correlation functions (ΔCCF). With the determination of the PSF by ITIR‐FCS and the optimization of measurement conditions ITIR‐FCS becomes a calibration‐free method. This allows us to provide measurements of absolute diffusion coefficients for bilayers with different compositions, which were stable over many different bilayer preparations over a time of at least one year, using a single PSF calibration.
Keywords:fluorescence spectroscopy  membrane  multiplexing  point spread function  total internal reflection
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号