Introduction of multiple γ-ray detection to charged particle activation analysis |
| |
Authors: | Goto J Oshima M Sugawara M Yamaguchi Y Bi C Bamba S Morimoto T |
| |
Institution: | 1.Institute for Research Promotion, Niigata University, Niigata, 951-8510, Japan ;2.Japan Chemical Analysis Center, Sanno 295-3, Inage, Chiba, 263-0002, Japan ;3.Chiba Institute of Technology, Narashino, Chiba, 275-0023, Japan ; |
| |
Abstract: | Charged particle activation analysis (CPAA) is a rapid method with high accuracy which can analyze multi-elements simultaneously. Since multiple γ-ray detection method is expected to improve the detection efficiency and the signal-to-noise ratio, we study what design of the γ-ray detector array is the most suitable for CPAA. We take up four design candidates and investigated the responses by the radiation simulation code Geant 4. From the results, we have deduced the best design with 5 germanium detectors in close geometry. By inspecting the sensitivity in CPAA, the method is proved to be useful and applicable to 116 nuclides. |
| |
Keywords: | |
本文献已被 SpringerLink 等数据库收录! |
|