首页 | 本学科首页   官方微博 | 高级检索  
     

Temperature-insensitive optical Fabry–Perot flow measurement system with partial bend angle
摘    要:A flow measurement system consisting of an optical fiber Fabry–Perot(F-P) sensor and an elbow tube is proposed and demonstrated to realize flow measurements and eliminate thermal disturbance.Two F-P sensors are symmetrically mounted on the inner-wall surface of the elbow of 90° in order to eliminate the effect of thermal disturbance to the flow measurement accuracy.Experimental results show that the absolute phase difference is the square root of the fluid flow.It is consistent with the theoretical analysis,which proves that the flow measurement method can measure flow and eliminate the influence of thermal disturbance simultaneously.

本文献已被 CNKI 等数据库收录!