首页 | 本学科首页   官方微博 | 高级检索  
     


Simultaneous determination of cadmium and lead in wine by electrothermal atomic absorption spectrometry
Affiliation:1. Gdańsk University, Laboratory of Environmental Chemistry & Ecotoxicology, 63 Wita Stwosza Str., 80-952 Gdańsk, Poland;2. Institute of Medicinal Plants, Yunnan Academy of Agricultural Sciences, 650200 Kunming, China;3. College of Resources and Environment, Yuxi Normal University, 653100 Yuxi, Yunnan, China;4. College of Agronomy and Biotechnology, Yunnan Agricultural University, 650201 Kunming, China;1. Group of Applied Instrumental Analysis, Department of Chemistry, Federal University of São Carlos, P.O. Box 676, São Carlos SP 13560-970, Brazil;2. Department of Chemistry, Wake Forest University, Winston-Salem NC 27109, USA
Abstract:A method has been developed for the direct simultaneous determination of Cd and Pb in white and red wine by electrothermal atomic absorption spectrometry (ET-AAS) using a transversely heated graphite tube atomizer (THGA) with longitudinal Zeeman-effect background correction. The thermal behavior of both analytes during pyrolysis and atomization stages were investigated in 0.028 mol l−1 HNO3 and in 1+1 v/v diluted wine using mixtures of Pd(NO3)2+Mg(NO3)2 and NH4H2PO4+Mg(NO3)2 as chemical modifiers. With 5 μg Pd+3 μg Mg as the modifiers and a two-step pyrolysis (10 s at 400°C and 10 s at 600°C), the formation of carbonaceous residues inside the atomizer was avoided. For 20 μl of sample (wine+0.056 mol l−1 HNO3, 1+1, v/v) dispensed into the graphite tube, analytical curves in the 0.10–1.0 μg l−1 Cd and 5.0–50 μg l−1 Pb ranges were established. The characteristic mass was approximately 0.6 pg for Cd and 33 pg for Pb, and the lifetime of the tube was approximately 400 firings. The limits of detection (LOD) based on integrated absorbance (0.03 μg l−1 for Cd, 0.8 μg l−1 for Pb) exceeded the requirements of Brazilian Food Regulations (decree #55871 from Health Department), which establish the maximum permissible level for Cd at 200 μg l−1 and for Pb at 500 μg l−1. The relative standard deviations (n=12) were typically <8% for Cd and <6% for Pb. The recoveries of Cd and Pb added to wine samples varied from 88 to 107% and 93 to 103%, respectively. The accuracy of the direct determination of Cd and Pb was checked for 10 table wines by comparing the results with those obtained for digested wine using single-element ET-AAS, which were in agreement at the 95% confidence level.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号