首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Direct electron-transfer of myoglobin within a new zwitterionic gemini surfactant film and its analytical application for H2O2 detection
Authors:Wang Fang  Hu Shengshui
Institution:

aDepartment of Chemistry, Wuhan University, Wuhan 430072, China

bDepartment of Pharmaceutical Analysis, College of Pharmacy, Wuhan University, Wuhan 430072, China

cState Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Beijing 100080, China

Abstract:The direct electron-transfer of myoglobin in a new zwitterionic gemini surfactant film with glassy carbon electrode surface has been investigated. A pair of well-defined and quasi-reversible voltammetric peaks was observed at −0.34 and −0.30 V due to the direct electron-transfer of the redox couple of Mb (FeIII/FeII). The voltammetric responses of myoglobin–surfactant film under different pH and scan rate conditions were obtained. The presence of hydrogen peroxide changed the typical electrochemical behaviors in terms of bioelectrocatalysis of myoglobin to hydrogen peroxide, and a higher sensitive electroanalytical method for the determination of hydrogen peroxide has been developed.
Keywords:Direct electron-transfer  Myoglobin  Gemini surfactant  Biosensor  Hydrogen peroxide
本文献已被 ScienceDirect PubMed 等数据库收录!