首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Preparation of glycerol dimethacrylate-based polymer monolith with unusual porous properties achieved via viscoelastic phase separation induced by monodisperse ultra high molecular weight poly(styrene) as a porogen
Authors:Aoki Hiroshi  Kubo Takuya  Ikegami Tohru  Tanaka Nobuo  Hosoya Ken  Tokuda Daisuke  Ishizuka Norio
Institution:Department of Polymer Science and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto, Japan.
Abstract:The preparation of polymer-based monolith capillary was examined by the use of glycerol dimethacrylate (GDMA) as monomer and monodisperse standard polystyrene (PS) solution in chlorobenzene as porogen. Poly-GDMA monoliths were prepared in situ in test tubes with standard PS having the variety of molecular weight (defined as Mw hereafter) from 50,000 to 3,840,000, and their morphology was compared to that of poly-GDMA monolith prepared in situ with a poor porogenic solvent of GDMA. According to scanning electron micrograph (SEM) observation, the structure of poly-GDMA monolith prepared in situ with toluene as a poor porogenic solvent showed a typical agglomerated globular structure, whereas the morphology of poly-GDMA monolith prepared in situ with the polymer (PS) porogenic solution was transformed from the aggregated globule form to three dimensionally (3D) continuous skeletal structure with the increase of Mw of standard PS utilized. Along with this morphological transformation or change, in the case of poly-GDMA monolith prepared in situ with ultra high Mw standard PS porogenic solution, the pore size distribution showed a sharp bimodal distribution, with one peak being located around 4 nm in the mesopore range (2-50 nm) and the other peak located around 1-2 microm in the macropore range (>50 nm), respectively. The poly-GDMA capillaries were prepared in situ with toluene, low Mw (50,000, 600,000) PS solution in chlorobenzene and the above mentioned ultra high Mw PS solution in chlorobenzene as a porogen, respectively, and measured by mu-HPLC with benzene and n-alkyl phenyl ketone as solutes for the evaluation in aqueous methanol (MeOH/H(2)O = 50/50-80/20, v/v). The permeability of capillaries prepared in situ with ultra high Mw standard PS polymer porogenic solution was much larger, compared to those of the capillaries prepared in situ with low Mw standard PS polymer porogenic solution or with toluene as porogen. On the other hand, the column efficiency was better in the case of the capillary prepared in situ with the ultra high Mw PS solution than in the latter capillaries. Those observations indicated that the ultra high Mw standard PS polymer porogenic solution should delay dynamically the phase separation of polymerizing mixture because of its visco-elasticity and should contribute to the creation of three dimensionally continuous skeletal monolith structure better to afford high separation efficiency.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号