Event-related functional MR imaging of visual cortex stimulation at high temporal resolution using a standard 1.5 T imager
Affiliation:1. VA Palo Alto Healthcare System, Palo Alto, CA, 94304;2. Palo Alto Medical Foundation, Palo Alto, CA;3. Department of Medicine, University of Colorado Anschutz Medical Campus, Aurora, CO;4. Yale School of Medicine, New Haven, CT;1. Service de Radiologie, Hopital Bichat, APHP, University Paris Diderot, France;2. Service de Médecine Interne, Hopital Bichat, APHP, University Paris Diderot, France;3. Service d''Explorations Fonctionnelles, Hospital Bichat, APHP, University Paris Diderot, France;4. Service de Medecine Nucleaire, Hopital Bichat, APHP, University Paris Diderot, France;5. Service de Cardiologie, Hopital Bichat, APHP, University Paris Diderot, France;6. Service de Pneumologie, Hopital Bichat, APHP; University Paris Diderot, France;7. Service de Radiologie, Hopital Bichat, APHP, University Paris Diderot, and Inserm 1148, Paris, France
Abstract:The authors report the technical feasibility of measuring event-related changes in blood oxygenation for studying brain function in humans at high temporal resolution. Measurements were performed on a conventional wholebody 1.5 T clinical scanner with a nonactive-shielded standard gradient system of 1 ms rise time for a maximum gradient strength of 10 mT/m. The radiofrequency (RF) transmitting and receiving MR unit consists of a commercially available circular polarized head coil. Magnet shimming with all first-order coils was performed to the volunteer's head resulting in a magnetic field homogeneity of about 0.1–0.2 ppm. The measuring sequence used was a modified 3D, first-order flow rephased, FLASH sequence with reduced bandwidth = 40 Hz/pixel, TR = 80 ms, TE = 56 ms, flip angle = 40–50°, matrix = 64 × 128, field-of-view = 200–250 mm2, slice thickness = 4 mm, NEX = 1, 128 partitions, and a total single scan time of about 10 min. In this sequence the 3D gradient table was removed and the 3D partition-loop acts as a time-loop for sequential measurement of 128 or 32 consecutive images at the same slice position. This means that event-related functional MRI could be performed with an interscan delay of 80 ms for a series of 128 sequential images or with an interscan delay of 320 ms for a simultaneous measurement of four slices with a series of 32 sequential images for each slice. We used a TTL signal given by the gradient board at the beginning of every line-loop in the measuring sequence and a self-made “TTL-Divider-Box” for the event triggering. This box was used to count and scale down the TTL signals by a factor of 128 and to trigger after every 128th TTL signal a single white flash-light, which was seen by the volunteer in the dark room of the scanner with a period of 10.24 s. As a consequence, the resulting event-related scan data coincide at each line of the series of 128 sequential images, which were repeated in 128 × 80 ms or 32 × 320 ms for the single- or four-slice experiment, respectively. Visual cortex response magnitude measured was about 5–7% with an approximate Gaussian shape and a rise time from stimulus onset to maximum of about 3–4 s, and a fall time to the baseline of about 5–6 s after end of stimulus. The reported data demonstrate the feasibility of functional MRI studies at high temporal resolution (up to 80 ms) using conventional MR equipment and measuring sequence.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号