Institution:1. Department of Physics, University of Azad, Jammu & Kashmir, Muzaffarabad, Pakistan;2. University of Pelita Harapan, 1100 M.H. Thamrin Boulevard, Lippo Village, Tangerang 15811, Indonesia;3. Department of Computer Engineering, Bina Nusantara University, 9 K.H. Syahdan, Jakarta 14810, Indonesia;4. Faculty of Mathematics and Natural Sciences, Syiah Kuala University, Darussalam, Banda Aceh 23111, Indonesia;5. Faculty of Mathematics and Natural Sciences, Diponegoro University, Tembalang, Semarang 50275, Indonesia;6. Faculty of Mathematics and Natural Sciences, Jakarta State University, 10 Rawamangun, Jakarta, Indonesia;7. Krida Wacana Christian University, Jakarta 11470, Indonesia;8. Faculty of Mathematics and Natural Sciences, Udayana University, Kampus Bukit Jimbaran, Denpasar 80361, Bali, Indonesia;9. Research Center of Maju Makmur Mandiri Foundation, 40/80 Srengseng Raya, Jakarta 11630, Indonesia;10. Fukui Science Education Academy, Takagi Chuou 2 choume, Fukui 910-0804, Japan;11. Physics of Magnetism and Photonics Group, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, 10 Ganesha, Bandung 40132, Indonesia;1. Analytical & Testing Center, Sichuan University, No. 29 Wangjiang Road, Wuhou District, Chengdu, Sichuan 610064, PR China;2. Research Center of Analytical Instrumentation, Key Laboratory of Bio-resource and Eco-environment, Ministry of Education, College of Life Science, Sichuan University, No. 29 Wangjiang Road, Wuhou District, Chengdu, Sichuan 610064, PR China;3. Photocatalysis International Research Center, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan;4. College of Computer Science, Sichuan University, No. 24 South Section 1, Yihuan Road, Wuhou District, Chengdu, Sichuan 610065, PR China
Abstract:A new on-line vapor-generation nebulization (VGN) method is explored for non-metal detection by microwave plasma torch-mass spectrometry (MPT-MS). In the new method, a three-channel “Y” is used to introduce the sample and reactant solutions simultaneously into a nebulizer. The VGN method offers higher sampling efficiency than does simple nebulization and improves sensitivity roughly two-fold for the determination of non-metallic elements. The device is suggested to be of potential benefit also in the determination of species that do not readily form volatile products.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号