Abstract:A multi-residual method is described for the simultaneous determination of 23 personal care products (PCPs), which display a wide range of physicochemical properties, present at trace levels in water samples. A one-step procedure was developed based on solid-phase microextraction (SPME) coupled with GC-MS analysis. A chemometric approach consisting of an experimental design (design of experiments) was applied to systematically investigate how four operating parameters—extraction temperature and time and desorption temperature and time—affect extraction recovery of PCPs in water. The optimum SPME procedure operating conditions, those yielding the highest extraction recovery for all the compounds, were determined; they correspond to an extraction time of 90 min and temperature of 80 °C and a desorption time of 11 min and temperature of 260 °C. Under these optimized conditions, the SPME procedure shows good analytical performance characterized by high reproducibility (RSD% intra-day accuracy varying in the 0.01–1.3% range) as well as good linearity and low detection limits (LODs lower than 2 ppb for most of the investigated PCPs).