首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Inverse thermal analysis of the drying zone of the evaporator of an axially grooved heat pipe
Authors:Zied Lataoui  Cyril Romestant  Yves Bertin  Abdelmajid Jemni  Daniel Petit
Institution:1. Laboratoire d’Etudes Thermiques, UMR CNRS 6608, ENSMA, 1 Avenue Clément Ader, 86960 Futuroscope Cedex, France;2. Laboratoire d’Etude des Systèmes Thermiques et Energétiques, ENIM, Avenue Ibn El Jazzar, 5019 Monastir, Tunisia
Abstract:An inverse approach is performed to characterize the thermal behaviour of an axially grooved heat pipe, in steady state, for various operating conditions. For this purpose, an experimental set up, as well as a network conduction model, are developed to simulate the heat transfer in the wall at the evaporator section. The minimization of an objective function, taking into account the discrepancy between measured temperatures and computed ones, allows then the estimation of a heat transfer coefficient as well as the drying out front positions for all the axial grooves. Hence, at the burnout point, the significant temperature increase in the evaporator extremity is considered to be a direct consequence of the restriction of the evaporative zone. Therefore, the distribution of liquid phase in the capillary structure of the heat pipe can be obtained through the analysis of the measured temperature gradient in the evaporator section where the dry out front was expected to occur. Furthermore, the dry out front expansion can be observed when the input heat load is increased or when the adiabatic temperature is decreased. Introducing an adverse tilt angle also shows the effect of the puddle.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏