首页 | 本学科首页   官方微博 | 高级检索  
     


Thermal and friction characteristics of turbulent flow through rectangular and square ducts with transverse ribs and wire-coil inserts
Authors:Sujoy Kumar Saha
Affiliation:ENEA Casaccia Research Centre, Institute of Thermal Fluid Dynamics, Office Building F-20, Via Anguillarese 301, 00123 S.M. Galeria, Roma, Italy
Abstract:The heat transfer and the pressure drop characteristics of turbulent flow of air through rectangular and square ducts with internal transverse rib turbulators on two opposite surfaces of the ducts and with wire-coil inserts have been studied experimentally. Circular duct has also been used. The transverse ribs in combination with wire-coil inserts have been found to perform better than either ribs or wire-coil inserts acting alone. The flow friction and thermal characteristics are governed by duct aspect ratio, coil helix angle and wire diameter of the coil, rib height and rib spacing, Reynolds number and Prandtl number. Correlations developed for friction factor and Nusselt number have predicted the experimental data satisfactorily. It has been found that on the basis of constant pumping power, up to 35% heat duty increase occurs for the combined ribs and wire-coil inserts case compared to the individual ribs and wire-coil inserts cases in the measured experimental parameters space. On the constant heat duty basis, the pumping power has been reduced up to 20% for the combined enhancement geometry than the individual enhancement geometries.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号