铝灰及其浸出液中氟的测定
引用本文:高华杰,徐思琪,薛雍,庞小丽,刘晓晨,杨子良,张琳琳. 铝灰及其浸出液中氟的测定[J]. 中国无机分析化学, 2022, 12(2): 65-71
作者姓名:高华杰  徐思琪  薛雍  庞小丽  刘晓晨  杨子良  张琳琳
作者单位:北京北达智汇微构分析测试中心有限公司 北京,中国环境科学研究院国家环境保护危险废物鉴别与风险控制重点实验室 北京,北京北达智汇微构分析测试中心有限公司 北京,北京北达智汇微构分析测试中心有限公司 北京,北京北达智汇微构分析测试中心有限公司 北京,中国环境科学研究院国家环境保护危险废物鉴别与风险控制重点实验室 北京,北京北达智汇微构分析测试中心有限公司
基金项目:国家重点研发计划重点专项(No.2018YFC1902801)
摘    要:铝灰中的氟化物是铝灰中的环境危害因子.使用X射线荧光光谱(XRF)法、X射线衍射(XRD)法对15份铝灰样品进行了元素及物相组成检测,使用SPSS 25.0对数据进行因子分析和聚类分析,将15份样品分成四类,从每类中选择1~2个样品,共选取5份样品作为代表进行后续实验.使用离子色谱法和氟离子选择电极法对铝灰浸出液中氟离...

关 键 词:铝灰    因子分析  聚类分析  氟离子选择电极  离子色谱法  固体废弃物
收稿时间:2021-08-30
修稿时间:2021-11-16

Determination of Fluorine in Aluminum Ash and its Leaching Solution
Gao Huajie,Xu Siqi,Xue Yong,Pang Xiaoli,Liu Xiaochen,Yang Ziliang and zhanglinlin. Determination of Fluorine in Aluminum Ash and its Leaching Solution[J]. Chinese Journal of Inorganic Analytical Chemistry, 2022, 12(2): 65-71
Authors:Gao Huajie  Xu Siqi  Xue Yong  Pang Xiaoli  Liu Xiaochen  Yang Ziliang  zhanglinlin
Affiliation:Beijing Micro Structure Analytical Laboratory Co,Ltd BeiJing China,Chinese Research Academy of Environmental Sciences State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control BeiJing China,Beijing Micro Structure Analytical Laboratory Co,Ltd BeiJing China,Beijing Micro Structure Analytical Laboratory Co,Ltd BeiJing China,Beijing Micro Structure Analytical Laboratory Co,Ltd BeiJing China,Chinese Research Academy of Environmental Sciences State Environmental Protection Key Laboratory of Hazardous Waste Identification and Risk Control BeiJing China,Beijing Micro Structure Analytical Laboratory Co,Ltd
Abstract:The fluoride in aluminum ash is an environmental hazard factor in aluminum ash. The element and phase composition of 15 aluminum ash samples were detected using XRF and XRD, and the data was analyzed by factor analysis and cluster analysis using SPSS 25.0. The 15 samples were divided into four categories, and a total of 5 samples were selected from each category. The sample is used as a representative for follow-up tests. Ion chromatography and fluoride ion selective electrode were used to detect the fluoride ions in the aluminum ash leaching solution. The results of the two devices were not statistically different; the fluoride ion selective electrode was used to determine the fluorine content in the aluminum ash. A strategy of combining the measurement results of different fractionation volumes (1-10mL) with the addition of standard recovery is proposed, which can quickly and effectively identify whether interfering ions have an effect on the determination results, and infer the appropriate fractionation volume , The method precision test results show that the relative standard deviation of the measurement results is less than 10%, indicating that the method is accurate and reliable.
Keywords:Aluminum ash   fluorine   factor analysis   cluster analysis   fluoride ion selective electrode   ion chromatography