首页 | 本学科首页   官方微博 | 高级检索  
     

Sensitive electrochemical determination of α-fetoprotein using a glassy carbon electrode modified with in-situ grown gold nanoparticles,graphene oxide and MWCNTs acting as signal amplifiers
摘    要:


Sensitive electrochemical determination of α-fetoprotein using a glassy carbon electrode modified with in-situ grown gold nanoparticles,graphene oxide and MWCNTs acting as signal amplifiers
Gao,Yan-Sha,Zhu, Xiao-Fei,Yang, Tao-Tao,Xu, Jing-Kun,Lu, Li-Min,Zhang, Kai-Xin. Sensitive electrochemical determination of α-fetoprotein using a glassy carbon electrode modified with in-situ grown gold nanoparticles,graphene oxide and MWCNTs acting as signal amplifiers[J]. Mikrochimica acta, 2015, 182(11): 2027-2035. DOI: 10.1007/s00604-015-1537-1
Authors:Gao  Yan-Sha  Zhu   Xiao-Fei  Yang   Tao-Tao  Xu   Jing-Kun  Lu   Li-Min  Zhang   Kai-Xin
Affiliation:1.Jiangxi Key Laboratory of Organic Chemistry, Jiangxi Science and Technology Normal University, Nanchang, 330013, People’s Republic of China
;2.College of Science, Jiangxi Agricultural University, Nanchang, 330045, People’s Republic of China
;
Abstract:

The authors describe an electrochemical immunoassay for α-fetoprotein (α-FP) using a glassy carbon electrode (GCE) modified with a nanocomposite made from gold nanoparticles, graphene oxide and multi-walled carbon nanotubes (AuNPs/GO-MWCNTs) and acting as a signal amplification matrix. The nanocomposite was synthesized in a one-pot redox reaction between GO and HAuCl4 without using an additional reductant. The stepwise assembly of the immunoelectrode was characterized by means of cyclic voltammetry and electrochemical impedance spectroscopy. The interaction of antigen and antibody on the surface of the electrode creates a barrier for electrons and causes retarded electron transfer, this resulting in decreased signals in differential pulse voltammetry of hexacyanoferrate which is added as an electrochemical probe. Using this strategy and by working at a potential of 0.2 V (vs. SCE), a wide analytical range (0.01 - 100 ng∙mL‾1) is covered. The correlation coefficient is 0.9929, and the limit of detection is as low as 3 pg∙mL‾1 at a signal-to-noise ratio of 3. This electrochemical immunoassay combines the specificity of an immunological detection scheme with the sensitivity of an electrode modified with AuNPs and GO-MWCNTs.

Schematic illustration of the fabrication procedure of the immunosensor

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号