首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Minimum Detectable Mass Fraction of Localised Changes in Biological Matrices Using Neutrons in Transmission
Authors:Z Tabatabaian  N M Spyrou
Institution:(1) Department of Physics, University of Surrey, Guildford, Surrey, GU2 5XH, UK
Abstract:The value of the minimum detectable mass of an irregularity, which will change the neutron macroscopic cross section of a biological matrix by 1%, has been calculated by using neutron transmission technique. The biological matrices selected were ones in which neutron transmission provided better detection of elements than photon attenuation measurements. Best results were obtained, for the detection of bone marrow in bone (12.2 mg/g), Ca in bone (10 mg/g) and water in brain (6 mg/g). The minimum required number of neutrons and the exposure time required for the detection of irregularities in bone marrow have been calculated.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号