首页 | 本学科首页   官方微博 | 高级检索  
     检索      


An interlaboratory investigation on the use of high-performance thin layer chromatography to perform assays of lamivudine-zidovudine, metronidazole, nevirapine, and quinine composite samples
Authors:Kaale Eliangiringa  Risha Peter  Reich Eike  Layloff Thomas P
Institution:Muhimbili University of Health and Allied Sciences, School of Pharmacy, Laboratory for Pharmaceutical Analysis, PO Box 65013, Dares Salaam, Tanzania. elia.kaale@muhas.ac.tz
Abstract:Two laboratories extensively investigated the use of HPTLC to perform assays on lamivudine-zidovudine, metronidazole, nevirapine, and quinine composite samples. To minimize the effects of differences in analysts' technique, the laboratories conducted the study with automatic sample application devices in conjunction with variable-wavelength scanning densitometers to evaluate the plates. The HPTLC procedures used relatively innocuous, inexpensive, and readily available chromatography solvents used in the Kenyon or the Global Pharma Health Fund Minilabs TLC methods. The use of automatic sample applications in conjunction with variable- wavelength scanning densitometry demonstrated an average repeatability or within-laboratory RSD of 1.90%, with 73% less than 2% and 97% at 2.60% or less, and an average reproducibility or among-laboratory RSD of 2.74%.