摘    要:本文研究用ICP-AES法同时测定磷铁的主含量元素P和杂质元素Si、Mn、Ti、V、Cr的方法。采用碱熔酸化分解试样,选B为测P的内标元素,回收率为96%-102%,最大相对标准偏差为8.60%,大多数结果的相对标准偏差小于5%。

关 键 词:ICP-AES,磷铁,主含量,杂质元素

Simultaneous Determination of High Content and Impurity Elements in Ferro Phosphorus by ICP-AES
Wu Bangyou.Simultaneous Determination of High Content and Impurity Elements in Ferro Phosphorus by ICP-AES[J].Chinese Journal of Spectroscopy Laboratory,1996(3).
Authors:Wu Bangyou
Abstract:This paper studies the method for simultaneous determination of high content element P and impurity elements Si,Mn,Ti,V,Cr in Ferro Phosphorus by using ICP-AES. The sample is decomposed with alkali and acid.B is used as an internal standard element. The recoveries are in the range of 96%-102%.The RSD is less than 8. 60%.