A modified simplex method for multifactor optimization of selectivity in gas chromatography
作者姓名:WANG  Qin-Sun ZHU  Chang-Shou YAN  Bing-WenNational Laboratory of Elemento-Organic Chemistry  Nankai University  Tianjin  China
作者单位:WANG,Qin-Sun ZHU,Chang-Shou YAN,Bing-WenNational Laboratory of Elemento-Organic Chemistry,Nankai University,Tianjin 300071,China
基金项目:supported by the National Natural Science Foundation of China.
摘    要:A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor ( stationary phase loading, carrier gas flow rate and column temperature ) for separation of ten compounds in gas chromatography. A three factors factorial design was used. The method was based on a special polynomial established from fifteen preliminary runs, using resolution as the selection criterion, with connection to a general simplex method. Excellent agreement is found between the predicted data and the experimental results, and most of experiments required in the general simplex method can be omitted.


A modified simplex method for multifactor optimization of selectivity in gas chromatography
WANG,Qin-Sun ZHU,Chang-Shou YAN,Bing-WenNational Laboratory of Elemento-Organic Chemistry,Nankai University,Tianjin ,China.A modified simplex method for multifactor optimization of selectivity in gas chromatography[J].Chinese Journal of Chemistry,1995(2).
Authors:WANG  Qin-Sun ZHU  Chang-Shou YAN  Bing-WenNational Laboratory of Elemento-Organic Chemistry  Nankai University  Tianjin  China
Institution:WANG,Qin-Sun ZHU,Chang-Shou YAN,Bing-WenNational Laboratory of Elemento-Organic Chemistry,Nankai University,Tianjin 300071,China
Abstract:A computer-assisted advanced simplex method is presented for the simultaneous optimization of multifactor ( stationary phase loading, carrier gas flow rate and column temperature ) for separation of ten compounds in gas chromatography. A three factors factorial design was used. The method was based on a special polynomial established from fifteen preliminary runs, using resolution as the selection criterion, with connection to a general simplex method. Excellent agreement is found between the predicted data and the experimental results, and most of experiments required in the general simplex method can be omitted.
Keywords:Gas chromatography  stationary phase  carrier gas flow rate  column temperature  multifactor optimization  