首页 | 本学科首页   官方微博 | 高级检索  
     


The electrode responses of a tungsten bronze electrode differ in potentiometry and voltammetry and give access to the individual contributions of electron and proton transfer
Affiliation:1. Institute of Biochemistry, University of Greifswald, 17487 Greifswald, Germany;2. Pontificia Universidad Católica de Valparaiso, Chile;3. Institute of Physics, University of Greifswald, 17487 Greifswald, Germany
Abstract:A tungsten wire covered with Na0.75WO3 acts in potentiometry as a reversible pH electrode having a pH dependent open-circuit potential Eocp with nernstian slope. The mid-peak potential Emp of cyclic voltammograms also depends on pH. At low pH (e.g., pH 2) and slow scan rates (e.g., 2 mV s–1) the voltammetric response is almost completely reversible. At higher pH and faster scan rates, the voltammetric systems exhibit features of increasing irreversibility. Under the conditions of reversibility, the Eocp and Emp differ significantly. Eocp is determined by the proton transfer at the electrode surface; whereas Emp is determined by the electron transfer equilibrium tungsten(VI)/tungsten(V) and the proton transfer at the electrode surface. The difference between Eocp and Emp provides the individual thermodynamic contributions of electron and proton transfer to the overall pH dependent redox electrode. This is the first time that both contributions can be separated for an insertion electrochemical system (thin surface layer). It is also shown for the first time that the mechanism of an ion-sensitive electrode can differ in potentiometry and voltammetry.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号