Abstract: | Current acoustic techniques for studying cavitation dynamics are only readily applicable to single-bubble activity, while optical methods can only be used in transparent media. However, multi-bubble cavitation often occurs in opaque media such as biological tissue. Here, the signals received passively by each of the 64 channels of a diagnostic ultrasound array are used to localize and separate emissions from several bubble clusters cavitating in agar gel, thereby providing a method of observing cavitation dynamics. The method has a high spatiotemporal resolution and is applicable to cavitation in opaque media. |