Fast determination of phosphorus in honey,milk and infant formulas by electrothermal atomic absorption spectrometry using a slurry sampling procedure |
| |
Authors: | I. Ló pez-Garcí a,P. Viñ asR. Romero-Romero,M. Herná ndez-Có rdoba |
| |
Affiliation: | Department of Analytical Chemistry, Faculty of Chemistry, University of Murcia, E-30071 Murcia, Spain |
| |
Abstract: | A procedure for the electrothermal atomic absorption spectrometric determination of phosphorus in honey, milk and infant formulas using slurried samples is described. Suspensions prepared in a medium containing 50% v/v concentrated hydrogen peroxide, 1% v/v concentrated nitric acid, 10% m/v glucose, 5% m/v sucrose and 100 mg l− 1 of potassium were introduced directly into the furnace. For the honey samples, multiple injection of the sample was necessary. The modifier selected was a mixture of 20 μg palladium and 5 μg magnesium nitrate, which was injected after the sample and before proceeding with the drying and calcination steps. Calibration was performed using aqueous standards prepared in the same suspension medium and the graph was linear between 5 and 80 mg l− 1 of phosphorus. The reliability of the procedure was checked by comparing the results obtained by the new developed method with those found when using a reference spectrophotometric method after a mineralization step, and by analyzing several certified reference materials. |
| |
Keywords: | Electrothermal atomic absorption spectrometry Phosphorus Honey Milk Infant formula |
本文献已被 ScienceDirect 等数据库收录! |
|