首页 | 本学科首页   官方微博 | 高级检索  
     检索      


The determination of optimal treatment plans for Volumetric Modulated Arc Therapy (VMAT)
Authors:Pınar Dursun  Z Caner Taşkın  İ Kuban Altınel
Institution:Department of Industrial Engineering, Bo?aziçi University, Bebek, ?stanbul 34342, Turkey
Abstract:The success of radiation therapy depends on the ability to deliver the proper amount of radiation to cancerous cells while protecting healthy tissues. As a natural consequence, any new treatment technology improves quality standards concerning primarily this issue. Similar to the widely used Intensity Modulated Radiation Therapy (IMRT), the radiation resource is outside of the patient’s body and the beam is shaped by a multi-leaf collimator mounted on the linear accelerator’s head during the state-of-the-art Volumetric Modulated Arc Therapy (VMAT) as well. However, unlike IMRT, the gantry of the accelerator may rotate along one or more arcs and deliver radiation continuously. This property makes VMAT powerful in obtaining high conformal plans in terms of dose distribution; but the apertures are interdependent and optimal treatment planning problem cannot be decomposed into simpler independent subproblems as a consequence. In this work, we consider optimal treatment planning problem for VMAT. First, we formulate a mixed-integer linear program minimizing total radiation dose intensity subject to clinical requirements embedded within the constraints. Then, we develop efficient solution procedures combining Benders decomposition with certain acceleration strategies. We investigate their performance on a large set of test instances obtained from an anonymous real prostate cancer data.
Keywords:Integer programming  Benders decomposition  Radiation therapy  VMAT  Algorithms
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号