首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Experimental measurement of the four-dimensional coherence function for an undulator x-ray source
Authors:Tran C Q  Williams G J  Roberts A  Flewett S  Peele A G  Paterson D  de Jonge M D  Nugent K A
Institution:School of Physics, University of Melbourne, Victoria, 3010, Australia.
Abstract:A full measurement of the four-dimensional coherence function from an undulator beam line is reported. The analysis is based on the observation that the data are consistent with a coherence function that is mathematically separable. The effective source size can be altered by changing the width of the exit slit, and the complete coherence function is presented for two settings. We find, to within experimental error, that the four-dimensional complex degree of coherence can be described as a real Gaussian function that depends only on the difference of the spatial coordinates.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏