首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Fluorometric determination of nitrite with acetaminophen
Authors:Murad I H Helaleh  T Korenaga  
Abstract:A simple, sensitive and selective fluorometric method for the determination of nitrite is described. The fluorometric determination is based on the reaction of acetaminophen with nitrite in an acidic medium followed by alkalinization of the reaction which yields a highly fluorescent product, exhibit (λexem=325/430 nm). The optimum experimental conditions were studied. The fluorescene intensity is linear over a nitrite concentration of 0.08–1.3 μg/ml with a detection limit of 2.7 ng/ml (S/N=3). The effect of interferences from various metals/ions were studied. The proposed method is accurate, reproducible, shows satisfactory results and compares successfully with the reference method.
Keywords:Fluorometric  Determination  Nitrite  Water samples
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏