Detection of complement C4 with a piezoelectric immunosensor
作者姓名:胡继明  裴仁军  胡毅  曾云鹗
作者单位:Department of Analysis and Testing Science,Department of Chemistry,Wuhan University,Wuhan,Hubei 430072,China,Department of Analysis and Testing Science,Department of Chemistry,Wuhan University,Wuhan,Hubei 430072,China,Department of Analysis and Testing Science,Department of Chemistry,Wuhan University,Wuhan,Hubei 430072,China,Department of Analysis and Testing Science,Department of Chemistry,Wuhan University,Wuhan,Hubei 430072,China
基金项目:Project supported by the National Natural Science Foundation of China.
摘    要:A piezoelectric immunosensor has been developed for the detection of complement C4. Anti-C4 antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. The coated crystal with the physical adsorption method to immobilize antibody showed the better results than the polyethyleneimine adhesion, glutaraldehyde cross-linking method with respect to sensitivity and reproducibility. The antibody-bound crystal with the physical adsorption method was successfully used for the detection of human complement C4 in the concentration range of 0.1-10 μg/mL for 40 min incubation time. The immunosensor system had good selectivity, and other materials in human serum did not interfere the detection remarkably. The crystal could be regenerated nearly 15 times when the bound materials on the crystal surface were eluted by strong acid and strong alkali solutions and subsequently cleaned in a ultrasonic cleaner.


Detection of complement C4 with a piezoelectric immunosensor
HU,Ji-Ming PEI,Ren-JunHU,Yi ZENG,Yun-E.Detection of complement C4 with a piezoelectric immunosensor[J].Chinese Journal of Chemistry,1998,16(3):219-225.
Authors:HU  Ji-Ming PEI  Ren-JunHU  Yi ZENG  Yun-E
Institution:HU,Ji-Ming PEI,Ren-JunHU,Yi ZENG,Yun-EDepartment of Analysis and Testing Science,Department of Chemistry,Wuhan University,Wuhan,Hubei 430072,China
Abstract:A piezoelectric immunosensor has been developed for the detection of complement C4. Anti-C4 antibody was immobilized onto the gold electrodes of a 9 MHz AT-cut piezoelectric crystal. The coated crystal with the physical adsorption method to immobilize antibody showed the better results than the polyethyleneimine adhesion, glutaraldehyde cross-linking method with respect to sensitivity and reproducibility. The antibody-bound crystal with the physical adsorption method was successfully used for the detection of human complement C4 in the concentration range of 0.1—10 μg/mL for 40 min incubation time. The immunosensor system had good selectivity, and other materials in human Serum did not interfere the detection remarkably. The crystal could be regenerated nearly 15 times when the bound materials on the crystal surface were eluted by strong acid and strong alkali solutions and subsequently cleaned in a ultrasonic cleaner.
Keywords:Piezoelectric immunosensor  complement C4  antibody immobilization  regeneration