Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography
Authors:Jiao Shuliang  Wang Lihong V
Abstract:A double-beam polarization-sensitive system based on optical coherence tomography was built to measure the Mueller matrix of scattering biological tissue with high spatial resolution. The Jones matrix of a sample can be determined with a single scan and subsequently converted into an equivalent nondepolarizing Mueller matrix. As a result, the system can be used to measure the Mueller matrix of an unstable sample, such as soft tissue. The polarization parameters of a porcine tendon, including magnitude and orientation of birefringence and diattenuation, were extracted by decomposition of the measured Mueller matrix.
Keywords: