首页 | 本学科首页   官方微博 | 高级检索  
     检索      

基于光子集成芯片的可穿戴光纤光栅解调研究
引用本文:李鸿强,毛泉桦,安芷萱,林志琳,王英杰,孟文涛,朱智越,张振,Juan DanielPrades Garcia.基于光子集成芯片的可穿戴光纤光栅解调研究[J].应用光学,2023,44(1):219-225.
作者姓名:李鸿强  毛泉桦  安芷萱  林志琳  王英杰  孟文涛  朱智越  张振  Juan DanielPrades Garcia
作者单位:1.天津工业大学 电子与信息工程学院 天津市光电检测技术与系统重点实验室,天津 300387
基金项目:国家自然科学基金(61675154);天津市重点研发计划项目(19YFZCSY00180);天津市科技计划项目(20YDTPJC01380)
摘    要:为了实现光纤光栅传感器在可穿戴系统中的应用,提出了一种基于硅基光子集成芯片的可穿戴光纤光栅传感解调系统。基于比利时iSiPP50G工艺的光子集成芯片由4×1长波长VCSEL阵列、1×8阵列波导光栅、2×2 MMI耦合器、4×1光纤光栅耦合器阵列、Ge-on-Si波导光电探测器、直波导和弯曲波导等组成。在完成对VCSEL光源金线键合和光子集成芯片光纤耦合封装的基础上,设计了手环式解调电路,对人体温度和心音信号进行了实时测量。实验结果表明:解调系统的动态波长检测范围为1 540 nm~1 560 nm,波长分辨率为0.08 pm,解调精度为5 pm,温度监测范围为35℃~42℃,误差为±0.1℃;可检测50 Hz~100 Hz频率范围内的心音信号,可识别出第一心音和第二心音,并计算出心动周期、心率、第一心音时限、第二心音时限和心力等特征参数。

关 键 词:光纤光栅传感解调  光子集成芯片  温度  心音  可穿戴
收稿时间:2022-05-02

Wearable fiber grating demodulation based on photonic integrated chip
Institution:1.Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronics and Information Engineering, Tianjin Polytechnic University, Tianjin 300387, China2.School of Computer Science and Technology, Tianjin Polytechnic University, Tianjin 300387, China3.Department of Electronic and Biomedical Engineering,University of Barcelona, Barcelona E-08028, Spain
Abstract:In order to realize the application of fiber grating sensor in wearable system, a wearable fiber grating sensor demodulation system based on silicon-based photonic integrated chip was proposed. The photonic integrated chip based on Belgium iSiPP50G process was composed of 4×1 long wavelength VCSEL array, 1×8 array waveguide grating, 2×2 MMI coupler, 4×1 fiber grating coupler array, GE-on-SI waveguide photodetector, straight waveguide and curved waveguide, etc. After completing the gold wire bonding of the VCSEL light source and the optical fiber coupling package of the photonic integrated chip, a wristband demodulation circuit was designed to measure the human body temperature and heart sound signals in real time. The experimental results show that the dynamic wavelength detection range of the demodulation system is 1 540 nm~1 560 nm, the wavelength resolution is 0.08 pm, the demodulation accuracy is 5 pm, the temperature monitoring range is 35 ℃~42 ℃, and the error is ±0.1 ℃. It can detect the heart sound signal in the frequency range of 50 Hz~100 Hz, identify the first heart sound and the second heart sound, and calculate the cardiac cycle, heart rate, the first heart sound time limit, the second heart sound time limit and cardiac parameters.
Keywords:
点击此处可从《应用光学》浏览原始摘要信息
点击此处可从《应用光学》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号