首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of ammonium in river water and sewage samples by capillary zone electrophoresis with direct UV detection
Authors:Fukushi Keiichi  Ito Hideyuki  Kimura Kenichi  Yokota Kuriko  Saito Keiitsu  Chayama Kenji  Takeda Sahori  Wakida Shin-ichi
Institution:Faculty of Maritime Sciences, Kobe University, 5-1-1 Fukaeminami-machi, Kobe 658-0022, Japan. fukushi@maritime.kobe-u.ac.jp
Abstract:We developed capillary zone electrophoresis (CZE) with direct UV detection for determination of ammonium in environmental water samples. Ammonium in the samples was partly converted into ammonia in the alkaline background electrolyte (BGE) during migration and was detected by molecular absorption of ammonia at 190 nm in approximately 7 min. The limit of detection (LOD) for ammonium was 0.24 mg/l (as nitrogen) at a signal-to-noise ratio of three. The respective values of the relative standard deviation (RSD) of peak area, peak height, and migration time for ammonium were 2.1, 1.8, and 0.46%. Major alkali and alkaline earth metal ions coexisting in the samples did not interfere with ammonium determination by the proposed method. The proposed method determined ammonium in surface water and sewage samples. The results were compared to those obtained using ion chromatography (IC).
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号