首页 | 本学科首页   官方微博 | 高级检索  
     


Electrocapillary potentiometric determination of anionic surfactants in detergents
Authors:Milan Sak-Bosnar  Momir S. Jovanović
Affiliation:(1) Research and Development Institute, Saponia Chemical Industry, Osijek;(2) Institute for Analytical Chemistry, Faculty of Technology and Metallurgy, University of Beograd, Beograd
Abstract:Summary An attempt has been made to use electrocapillarity for potentiometric determinations of anionic surfactants. A sitting mercury drop indicator electrode was successfully used for these titrations. Anionic surfactants should be titrated in a solution of defined ionic strength (0.8% sodium sulphate) at any pH between 3 and 10. A cationic surfactant (Hyamine 1622) should be used as the titrant. Pure anionic surfactants, technical grade anionic surfactants and anionic surfactants in model detergents have all been successfully titrated.
Elektrokapillare Potentiometrie anionischer Tenside
Zusammenfassung Der Elektrokapillareffekt wurde zur potentiometrischen Bestimmung anionischer Tenside auszunutzen versucht. Als Indikatorelektrode wurde mit Erfolg eine J-förmige Hg-Elektrode (Elektrode mit aufsitzendem Hg-Tropfen) benutzt. Die Titration anionischer Tenside wird in einer Lösung bestimmter Ionenstärke (0,8% Natriumsulfat) und im pH-Bereich 3–10 durchgeführt. Als Titrant verwendet man dazu ein kationisches Tensid (Hyamin 1622). Reine anionische Tenside, technische anionische Tenside und anionische Tenside in einem Modellwaschmittel wurden titriert.


Presented at the 8th International Microchemical Symposium, Graz, August 25–30, 1980.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏