Simultaneous determination of angiotensins II and 1-7 by capillary zone electrophoresis in plasma and urine from hypertensive rats |
| |
Authors: | Fermí n Alejandro Tenorio-Ló pez,Gabriela Zarco-Olvera,Martí n Rosas-Peralta,Leonardo del Valle-Mondragó n |
| |
Affiliation: | a Departamento de Farmacología, Instituto Nacional de Cardiología “Ignacio Chávez”, Juan Badiano No. 1, Col. Sección XVI, 14080 Tlalpan, México D.F., Mexico b Departamento de Cardiología Adultos III, Instituto Nacional de Cardiología “Ignacio Chávez”, Juan Badiano No. 1, Col. Sección XVI, 14080 Tlalpan, México D.F., Mexico |
| |
Abstract: | We describe the procedure developed for the simultaneous detection and quantification of angiotensin II and angiotensin-(1-7), by capillary zone electrophoresis with UV detection by photodiode-array, at a wavelength of 200 nm, in the plasma and urine from hypertensive rats. Optimal separation was achieved with a 100 mM boric acid + 3 mM tartaric acid + 10 fM gold (III) chloride electrolyte solution at pH 9.80. The applied voltage was 30 kV and the capillary temperature was kept constant at 20 °C. The method was over the concentration range of 0.01-500 pmol/mL. All determination coefficients were higher or equal to 0.9985. Limits of detection and quantification for angiotensin II were 0.0110 pmol/mL (S/N = 3) and 0.0195 pmol/mL (S/N = 5), respectively. While for angiotensin-(1-7), the limits were 0.0112 pmol/mL (S/N = 3) and 0.0193 pmol/mL (S/N = 5), respectively. The present method offers a time-saving way to simultaneous determination of angiotensin II and angiotensin-(1-7), since it can be completed in 10 min, compared to other methodologies reported in the literature for capillary electrophoresis and liquid chromatography, which require more than 1 h for analysis of complex matrices, such as plasma and urine. The procedure is illustrated by experiments that quantify simultaneously angiotensin II and angiotensin-(1-7) in plasma and urine from hypertensive and normotensive rats, with and without antihypertensive treatment. The levels of angiotensin II and angiotensin-(1-7) detected in the experimental model, resulted in a recovery of 99.00-106.01% and a reproducibility of less than 10%. The proposed analytical method is a use full tool for the simultaneous detection of angiotensin II and angiotensin-(1-7) implicated in vascular remodeling in pathologies such as hypertension. |
| |
Keywords: | Angiotensin II Angiotensin-(1-7) Capillary zone electrophoresis Hypertension |
本文献已被 ScienceDirect 等数据库收录! |
|