首页 | 本学科首页   官方微博 | 高级检索  
     


Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography-tandem mass spectrometry
Authors:Ariel R. Fontana  Luis D. Martinez  Jorgelina C. Altamirano
Affiliation:a Grupo de Investigación y Desarrollo en Química Analítica (QUIANID) (LISAMEN, CCT CONICET - Mendoza), Av. Ruiz Leal S/N, Parque General San Martín, 5500 Mendoza, Argentina
b Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, Argentina
c INQUISAL-CONICET, Departamento de Química Analítica, Facultad de Química, Bioquímica y Farmacia, Universidad Nacional de San Luis, Argentina
d Instituto de Ciencias Básicas, Universidad Nacional de Cuyo, Parque General San Martín, Mendoza, Argentina
Abstract:Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 μL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g−1. The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g−1 for BDE-47, 0.09-1000 ng g−1 for BDE-100, 0.10-1000 ng g−1 for BDE-99 and 0.19-1000 ng g−1 for BDE-153 and the coefficients of estimation were ≥0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g−1) and by comparing with a reference Soxhlet technique. Recovery values were ≥80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples.
Keywords:Polybrominated diphenyl ethers   Ultrasound-assisted leaching-dispersive solid-phase extraction   Dispersive liquid-liquid microextraction   Sediment analysis   Gas chromatography-mass spectrometry
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号