首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Determination of marker pteridins and biopterin reduced forms, tetrahydrobiopterin and dihydrobiopterin, in human urine, using a post-column photoinduced fluorescence liquid chromatographic derivatization method
Authors:Florentina Cañada-Cañada  Anunciación Espinosa-Mansilla  Arsenio Muñoz de la Peña  Alicia Mancha de Llanos
Institution:Department of Analytical Chemistry, University of Extremadura, 06071 Badajoz, Spain
Abstract:A liquid chromatographic method for the simultaneous analysis of marker pteridins and biopterin reduced forms, in urine samples is proposed. A Zorbax Eclipse XDB-C18 column was used for the chromatographic separation, using a 98/2 (v/v), citrate buffer (pH 5.5)-acetonitrile mobile phase, in isocratic mode. A post-column photoderivatization was carried out with an on-line photoreactor, located between a diode array detector (DAD) and a fast scanning fluorescence detector (FSFD). Neopterin (NEO), biopterin (BIO), pterin (PT) and dihydrobiopterin (BH2) were determined by measuring native fluorescence, using the photoreactor in OFF-mode, and tetrahydrobiopterin (BH4) was determined by measuring of the induced fluorescence of the generated photoproducts, using the photoreactor in ON-mode. In addition, Creatinine (CREA), as a reference of metabolites excrection in urine, was simultaneously determined using the DAD detector. Detection limits were 0.2, 13.0, 0.3, 0.3 and 3.5 ng mL−1, for NEO, BH2, BIO, PT and BH4, respectively, and 0.4 μg mL−1 for CREA. Ratio values for NEO/CREA, PT/CREA, BH4/CREA, BH2/CREA, NEO/BIO and BIOtotal/CREA, in urine samples, of healthy children and adults, phenylketonuric children and infected mononucleosis children, are reported. A comparative study, about the mean values obtained for each of the compounds, by the present procedure and by the classical iodine oxidation method (Fukushimás method), has been performed, in urine samples belonging to healthy volunteers. The values obtained were BH4/CREA: 0.41, BH2/CREA: 0.31 and BIOtotal/CREA: 0.73, by the proposed method, and BH4/CREA: 0.35, BH2/CREA: 0.20 and BIOtotal/CREA: 0.48, by iodine oxidation method.
Keywords:BH4  tetrahydrobiopterin  GTP  guanosine triphosphate  PAH  phenylalanine-4-hydroxylase  TH  tyrosine-3-hydroxylase  TPH  tryptophan-5-hydroxylase  BH2  dihydrobiopterin  DHPR  dihydropteridine reductase  NEO  neopterin  BIO  biopterin  ISO  isoxanthopterin  PT  pterin  HPA  hyperphenylalaninaemia  PKU  phenylketonuria  6-PTS  6-pyruvoyltetrahydropterin synthase  DTE  dithioerythritol  DTT  dithiothreitol  DAD  diode array detector  FSFD  fast scanning fluorescence detector  CREA  creatinine  HPAs  hyperphenylalaninaemias
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号