首页 | 本学科首页   官方微博 | 高级检索  
     

氧碘化学激光器故障诊断技术
引用本文:张政, 张世强, 孙艳宏. 氧碘化学激光器故障诊断技术[J]. 强激光与粒子束, 2014, 26: 101014. doi: 10.11884/HPLPB201426.101014
作者姓名:张政  张世强  孙艳宏
作者单位:1.西北核技术研究所 激光与物质相互作用国家重点实验室, 西安 71 0024
基金项目:激光与物质相互作用国家重点实验室基金项目(SKLLIM1204)
摘    要:为了解决氧碘化学激光器通过常规诊断故障定位困难的问题,采用建立的氧碘化学激光器功率失常故障树模型,结合氧碘化学激光器常用的8个监测参数:碘腔压力、碘文氏管压力、p-t曲线、主氦压力、氯气压力、氧发生器压力、上游压力和光腔压力,提出采用故障树和在线监测参数相结合的办法,基于3法则的判断标准对氧碘化学激光器进行故障诊断,故障诊断正确率达到94.5%,并对出现的故障提出了改进措施。

关 键 词:氧碘化学激光器   故障诊断   故障树   在线监测
收稿时间:2013-12-05
修稿时间:2014-07-05

Fault diagnosis study for chemical oxygen iodine laser
Zhang Zheng, Zhang Shiqiang, Sun Yanhong. Fault diagnosis study for chemical oxygen iodine laser[J]. High Power Laser and Particle Beams, 2014, 26: 101014. doi: 10.11884/HPLPB201426.101014
Authors:Zhang Zheng  Zhang Shiqiang  Sun Yanhong
Affiliation:1. State Key Laboratory of Laser Interaction with Matter,Northwest Institute of Nuclear Technology,Xi’an 710024,China
Abstract:It is difficult to find out fault chemical oxygen iodine laser (COIL) because of its complex structure and interactions between the subsystems. To solve the COIL fault diagnostic problems, along with the development of integrate and practical COILs, it is required for keeping the device performance and reducing the maintenance cost and human resource input. Fault analysis of COILs has been done based on the fault tree analysis method. The fault tree of a COIL was established combining with on-line monitoring parameters: iodine cavity pressure, iodine venturi pressure, p-t curve, main helium pressure, chlorine pressure, single oxygen generator pressure, upstream pressure, optical cavity pressure. According to the 3 rule, the accuracy of fault diagnosis for the COIL is 94.5%. Furthermore, improvement put suggestions has been forward.
Keywords:chemical oxygen iodine laser  fault diagnosis  fault tree  on-line monitoring
本文献已被 CNKI 等数据库收录!
点击此处可从《强激光与粒子束》浏览原始摘要信息
点击此处可从《强激光与粒子束》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏