首页 | 本学科首页   官方微博 | 高级检索  
     

双腔热解光腔衰荡光谱仪测量大气中NO2和RNO2
引用本文:陈剑,吴昊,刘安雯,胡水明,张劲松. 双腔热解光腔衰荡光谱仪测量大气中NO2和RNO2[J]. 化学物理学报, 2017, 30(5): 493-498
作者姓名:陈剑  吴昊  刘安雯  胡水明  张劲松
作者单位:中国科学技术大学, 合肥微尺度国家实验室(筹), 合肥 230026;加州大学河滨分校化学系及空气污染研究中心, 加州 92521,中国科学技术大学, 合肥微尺度国家实验室(筹), 合肥 230026,中国科学技术大学, 合肥微尺度国家实验室(筹), 合肥 230026,中国科学技术大学, 合肥微尺度国家实验室(筹), 合肥 230026,中国科学技术大学, 合肥微尺度国家实验室(筹), 合肥 230026;加州大学河滨分校化学系及空气污染研究中心, 加州 92521
基金项目:This work was supported from the Ministry of Sci- ence and Technology of China (No.2013CB834602 and 2013BAK12B00), the National Natural Science Foun- dation of China (No.21427804 and No.21225314).
摘    要:

收稿时间:2017-05-02

Field Measurement of NO2 and RNO2 by Two-Channel Thermal Dissociation Cavity Ring Down Spectrometer
Jian Chen,Hao Wu,An-wen Liu,Shui-ming Hu and Jingsong Zhang. Field Measurement of NO2 and RNO2 by Two-Channel Thermal Dissociation Cavity Ring Down Spectrometer[J]. Chinese Journal of Chemical Physics, 2017, 30(5): 493-498
Authors:Jian Chen  Hao Wu  An-wen Liu  Shui-ming Hu  Jingsong Zhang
Affiliation:Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Tech-nology of China, Hefei 230026, China;Department of Chemistry and Air Pollution Research Center, University of California, Riverside, California 92521, America,Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Tech-nology of China, Hefei 230026, China,Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Tech-nology of China, Hefei 230026, China,Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Tech-nology of China, Hefei 230026, China and Hefei National Laboratory for Physical Sciences at the Microscale, University of Science and Tech-nology of China, Hefei 230026, China;Department of Chemistry and Air Pollution Research Center, University of California, Riverside, California 92521, America
Abstract:A two-channel thermal dissociation cavity ring down spectroscopy (CRDS) instrument has been built for in situ, real-time measurement of NO2 and total RNO2 (peroxy nitrates and alkyl nitrates) in ambient air, with a NO2 detection limit of 0.10 ppbv at 1 s. A 6-day long measurement was conducted at urban site of Hefei by using the CRDS instrument with a time resolution of 3 s. A commercial molybdenum converted chemiluminescence (Mo-CL) instrument was also used for comparison. The average RNO2 concentration in the 6 days was measured to be 1.94 ppbv. The Mo-CL instrument overestimated the NO2 concentration by a bias of +1.69 ppbv in average, for the reason that it cannot distinguish RNO2 from NO2. The relative bias could be over 100% during the afternoon hours when NO2 was low but RNO2 was high.
Keywords:Cavity ring-down spectroscopy  Molybdenum converted chemiluminescence  Thermal dissociation  Organic nitrates
点击此处可从《化学物理学报》浏览原始摘要信息
点击此处可从《化学物理学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号