首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of pyrolysis mass spectrometry with high performance liquid chromatography for the analysis of Cremophor EL in drugs and serum
Authors:Ghassempour Alireza  Nabid Mohammad Reza  Talebi Mohammad  Entezami Ali Akbar
Affiliation:a Chemical Research Center, Faculty of Science, Shahid Beheshti University, Evin, Tehran, Iran
b Department of Chemistry, Faculty of Science, Shahid Beheshti University, Evin, Tehran, Iran
c Faculty of Chemistry, Tabriz University, Tabriz, Iran
Abstract:Polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL: CrEL) is a solubilization agent for hydrophobic drugs. Recently, CrEL has shown some side effects in patients. In the present work, we introduce pyrolysis-mass spectrometry (Py-MS) for the determination of CrEL in drugs and blood samples. Mass to charge (m/z) values of 89 and 138 of CrEL and 3-nitroaniline (as internal standard), respectively, were used for quantitative measurements by selected ion monitoring (SIM) method. At a probe pyrolysis temperature range of 350-450 °C the results are highly reproducible. Limit of detection (LOD), linearity and relative standard deviation (R.S.D., n=5) were determined to be 1 ng ml−1, 10 ng ml−1-100 mg ml−1 and 1.3%, respectively. The results of Py-MS are compared with those obtained by high performance liquid chromatography (HPLC) and show that time for analysis, sensitivity and linearity are far better.
Keywords:Pyrolysis   Mass spectrometry   Cremophor EL   HPLC
本文献已被 ScienceDirect PubMed 等数据库收录!