首页 | 本学科首页   官方微博 | 高级检索  
     


Ethylene oxide pollution evaluation Part II: Sampling on HBr-treated charcoal tubes
Authors:C. Lefevre  P. Ferrari  J. Delcourt  J. P. Guenier  J. Muller
Affiliation:(1) Institut National de Recherche et de Sécurité (I.N.R.S.), Avenue de Bourgogne, B.P. 27, 54500 Vandoeuvre, France
Abstract:Summary Air sampling of ethylene oxide on HBr-treated charcoal tubes followed by capillary GC analysis of the 2-bromoethanol produced allows pollution control evaluation for concentrations ranging from 0.2 to 20 mgm−3. The adequacy of the method is assessed taking into account ambient temperature and relative humidity.
Keywords:Gas chromatography  Ethylene oxide  HBr-treated charcoal tubes  Pollution