首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Highly sensitive fluorescence quantification of picloram using immunorecognition liposome
Authors:Zhang Yi  Zeng Guang-Ming  Tang Lin  Niu Cheng-Gang  Pang Ya  Chen Li-Juan  Feng Chong-Ling  Huang Guo-He
Institution:a College of Environmental Science and Engineering, Hunan University, Changsha 410082, China
b Key Laboratory of Environmental Biology and Pollution Control (Hunan University), Ministry of Education, Changsha 410082, China
Abstract:Picloram is a widely used chlorinated herbicide, which is quite persistent and mobile in soil and water with adverse health and environmental risks. A simple and efficient method with high sensitivity and good selectivity was developed in this work to analyze picloram. The aldehyde group functionalized quartz glass plate was used to catch picloram by Schiff base reaction, and reacted with the liposomes-labeled antibody. The fluorescein isothiocyanate (FITC) solution was encapsulated in the liposomes. After being released from the liposomes, the fluorescence of FITC was measured by a fluorimeter. It was found that the fluorescence intensity is linearly correlated to the logarithm of picloram concentration, ranging from 1.0 × 10−4 to 100 ng mL−1, with a detection limit of 1.0 × 10−5 ng mL−1. Picloram concentration in real wastewater samples were accurately measured by the proposed method and HPLC, the results of the two methods were approximately the same. The proposed method showed high sensitivity and good selectivity, and could be an efficient tool for picloram quantitative analysis.
Keywords:Picloram  Fluorescence  Sensitivity  Liposome  Antibody
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号