首页 | 本学科首页   官方微博 | 高级检索  
     


Sample geometry and efficiency determination of bremsstrahlung radiation of 90Sr on gamma detection systems
Authors:Ş. Turhan  A. Zarars?z  H. Yücel
Affiliation:24301. Sarayk?y Nuclear Research and Training Center (SNRTC), 06983 Sarayk?y, Ankara, Turkey
24302. Sarayk?y Nuclear Research and Training Center (SNRTC), 06983 Sarayk?y, Ankara, Turkey
24303. Sarayk?y Nuclear Research and Training Center (SNRTC), 06983 Sarayk?y, Ankara, Turkey
Abstract:Summary The bremsstrahlung radiation energy spectra were produced by hard beta-emitters the 90Sr-90Y contaminated tea sample sources placed in a copper cylinder (cylinder counting geometry) and encapsulated in two Cu discs (sandwich counting geometry). These energy spectra were directly measured by using two separate gamma-ray spectrometers with a coaxial 110% efficient HpGe detector and a 110 cm3 HpGe well-type detector. The minimum detectable activity and the absolute efficiency of beta-activity for the sandwich and cylinder geometries were found to be 23 Bq . kg-1 and (1.67±0.04)% and 55 Bq . kg-1 and (2.61±0.05)%, respectively. These results indicate that the bremsstrahlung radiation counting method can be applied to some environmental studies when high efficient HpGe detectors, especially well-type HpGe are used.
Keywords:
本文献已被 SpringerLink 等数据库收录!