首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Reproducibility of cine displacement encoding with stimulated echoes (DENSE) in human subjects
Institution:1. Department of Radiology, Northwestern University, 737 N Michigan Avenue, Suite 1600, Chicago, IL, 60611;2. Department of Radiology, Anzhen Hospital, Capital Medical University, Beijing, 100029, China;1. Dept of Radiology, Sahyadri Speciality Hospital, Karve Road, Erandwane, Pune, 411004, Maharashtra, India;2. Dept of Vascular Surgery, Sahyadri Speciality Hospital, Karve Road, Erandwane, Pune, 411004, Maharashtra, India;3. Dept of General Surgery, Sahyadri Speciality Hospital, Karve Road, Erandwane, Pune, 411004, Maharashtra, India;1. Center for Advanced Imaging Innovation and Research, Bernard and Irene Schwartz Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, New York, NY 10016, USA;2. Department of Radiology, Duke University Medical Center, Durham, NC, 27710, USA;1. Department of Radiology, University of Chicago Medical Center, 5841 South Maryland Avenue, Chicago, IL 60637, USA;2. School of Electronic and Information Engineering, Beijing Jiaotong University, Beijing, China
Abstract:ObjectivesTo test the hypothesis that two-dimensional (2D) displacement encoding via stimulated echoes (DENSE) is a reproducible technique for the depiction of segmental myocardial motion in human subjects.Materials and methodsFollowing the approval of the institutional review board (IRB), 17 healthy volunteers without documented history of cardiovascular disease were recruited. For each participant, 2D DENSE were performed twice (at different days) and the images were obtained at basal, midventricular and apical levels of the left ventricle (LV) with a short-axis view. The radial thickening strain (Err), circumferential strain (Ecc), twist and torsion were calculated. The intra-, inter-observer and inter-study variations of DENSE-derived myocardial motion indices were evaluated using coefficient of variation (CoV) and intra-class correlation coefficient (ICC).ResultsIn total, there are 272 pairs of myocardial segments (data points) for comparison. There is good intra- and inter-observer reproducibility for all DENSE-derived measures in 17 participants. There is good inter-study reproducibility for peak Ecc (CoV = 19.64%, ICC = 0.8896, p < 0.001), twist (CoV = 33.11%, ICC = 0.9135, p < 0.001) and torsion (CoV = 13.96%, ICC = 0.8684, p < 0.001). There is moderate inter-study reproducibility for Err (CoV = 38.89%, ICC = 0.7022, p < 0.001).ConclusionDENSE is a reproducible technique for characterizing LV regional systolic myocardial motion on a per-segment basis in healthy volunteers.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号