Abstract:Abstract

A new coating procedure for different diffusion controlled preconcentration methods (tubular denuder, annular denuder, diffusion screen) is described for the determination of nitric acid in air. In this study, a silanization reaction is applied to obtain a chemically fixed coating with an end placed functional NH2-group, which can be used as a sink to collect acidic compounds from air. This coating must be carried out only once and can be used for a long time. The denuders, coated with this procedures, were compared with conventionally coated NaF denuders.
Keywords:Immobilization  nitric acid  diffusion controlled sampling  atmosphere