Three-dimensional magnetic field enhancement in a liner implosionsystem |
| |
Authors: | Shumlak U. Hussey T.W. Peterkin R.E. Jr. |
| |
Affiliation: | Dept. of Aeronaut. & Astronaut., Washington Univ., Seattle, WA; |
| |
Abstract: | The magnetic field enhancement is calculated for a magnetically imploded liner system that has flux excluding radial vanes. For the thinnest vane tested the field is found to concentrate at the vanes to a maximum value of almost three times its ambient value with a corresponding temperature increase well above the melting point. These values are calculated using the three-dimensional magnetohydrodgnamic code, MACH3. Calculations are performed for three vane thicknesses, and the vane movement is estimated. A bound is established on the design specification of the vanes based the disruption of current delivery to the liner due to the movement of the vanes |
| |
Keywords: | |
|
|