Optimization of dispersive liquid-liquid microextraction and improvement of detection limit of methyl tert-butyl ether in water with the aid of chemometrics |
| |
Authors: | Karimi Maryam Sereshti Hassan Samadi Soheila Parastar Hadi |
| |
Institution: | School of Chemistry, University College of Science, University of Tehran, P.O. Box 14155-64555, Tehran, Iran. |
| |
Abstract: | Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R(2)=0.9987 and F=17.83. The optimal conditions were 42.0 μL for extraction solvent, 0.30 mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range was 0.001-370 μg L(-1). The improved detection limit with the aid of chemometrics was 0.3 ng L(-1). The relative standard deviation (RSD) with n=9 for 0.1 mg L(-1) MTBE in water with and without internal standard was 2.7% and 3.1%, respectively. Under the optimal conditions, the relative recoveries of spiked MTBE in different water samples were in the range of 100-105%. |
| |
Keywords: | Dispersive liquid–liquid microextraction Methyl tert-butyl ether Gas chromatography–mass spectrometry Chemometrics |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|