Abstract:The performance of three implementations of pinhole-based camera models for use in common light-sheet imaging arrangements is investigated on the background of application to particle image velocimetry (PIV) and Doppler global velocimetry (DGV). Calibration data obtained from translated planar calibration targets was found to yield camera attitude within 0.1° on four different test cases with object distance varying as little as 2% depending on the choice of camera model. Camera calibration using data from a single image of coplanar points is considered a viable alternative to manual triangulation of camera positions but is restricted to off-normal viewing directions.
Contact InformationChristian E. WillertEmail:
Keywords:Digital imaging  Camera calibration  Camera model  Flow imaging  Image transformation  Doppler global velocimetry  Stereo particle image velocimetry