首页 | 本学科首页   官方微博 | 高级检索  
     检索      


Optical biosensor for the determination of BOD in seawater
Authors:Jiang Yaqi  Xiao Lai-Long  Zhao Li  Chen Xi  Wang Xiaoru  Wong Kwok-Yin
Institution:a Department of Chemistry and Key Laboratory of Analytical Sciences of the Ministry of Education, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
b State Key Laboratory of Marine Environmental Science, Xiamen University, Xiamen 361005, China
c The Hong Kong Polytechnic University, Hunghom, Kowloon, Hong Kong, China
Abstract:An automatic sensing system was developed using an optical BOD sensing film. The sensing film consists of an organically modified silicate (ORMOSIL) film embedded with an oxygen-sensitive Ru complex. A multi-microorganisms immobilization method was developed for the BOD sensing film preparation. Three different kinds of microorganisms, Bacillus licheniformis, Dietzia maris and Marinobacter marinus from seawater, were immobilized on a polyvinyl alcohol ORMOSILs. After preconditioning, the BOD biosensor could steadily perform well up to 10 months. The linear fluctuant coefficients (R2) in the range of 0.3-40 mg L−1 was 0.985 when a glucose/glutamate BOD standard was applied. The reproducible response for the BOD sensing film could be obtained within ±2.3% of the mean value in a series of 10 samples in 5.0 mg L−1 BOD standard GGA solution. The effects of temperature, pH and sodium chloride concentration on the two microbial films were studied as well. The BOD sensing system was tested and applied for the BOD determination of seawater.
Keywords:Optical BOD biosensor  ORMOSILs  Seawater
本文献已被 ScienceDirect PubMed 等数据库收录!