Determination of inorganic elements in animal feeds by NIRS technology and a fibre-optic probe |
| |
Authors: | González-Martín Inmaculada Alvarez-García Noelia González-Pérez Claudio Villaescusa-García Virginia |
| |
Institution: | Departamento de Química Analítica, Nutrición y Bromatología, Facultad de CC, Químicas, C/Plaza de la Merced s/n, 37008 Salamanca, España |
| |
Abstract: | In the present work we study the use of near infra-red spectroscopy (NIRS) technology together with a remote reflectance fibre-optic probe for the analysis of the mineral composition of animal feeds. The method allows immediate control of the feeds without prior sample treatment or destruction through direct application of the fibre-optic probe on the sample.The regression method employed was modified partial least squares (MPLS). The calibration results obtained using forty samples of animal feeds allowed the determination of Fe, Mn, Ca, Na, K, P, Zn and Cu, with a standard error of prediction (SEP(C)) and a correlation coefficient (RSQ) of 0.129 and 0.859 for Fe; 0.175 and 0.816 for Mn; 5.470 and 0.927 for Ca; 2.717 and 0.862 for Na; 4.397 and 0.891 for K; 2.226 and 0.881 for P; 0.153 and 0.764 for Zn, and 0.095 and 0.918 for Cu, respectively.The robustness of the method was checked by applying it to 10 animal feeds samples of unknown mineral composition in the external validation. |
| |
Keywords: | Animal feed Inorganic element Determination NIRS Fibre-optic probe |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|