Helium migration in palladium I. Concentration dependence of helium release
Authors:J B Holt  W Bauer  G J Thomas
Institution:1. Lawrence Radiation Laboratory , University of California , Livermore, California, 94550;2. Sandia Laboratories , Livermore, California, 94550;3. Sandia Laboratories , Albuquerque, New Mexico, 87115
Abstract:Abstract

High temperature gas release from helium-implanted palladium has been investigated for He/Pd atom fractions from 5 × 10?6 to 5 × 10?2. The temperature required for 25 per cent He release increases with increasing dose to an atom fraction of 10?4, where a sudden reversal occurs for higher concentrations. The release is associated with dramatic changes in the surface features of the palladium. A qualitative physical model is presented to explain the data.